BROWSE CATALOG
Go To SYJ5000 Valve
SYJ5000, 5 Port Solenoid Valve, Base Mounted & Body Ported
  • Fluid: air
  • Operating pressure range: 0.1 - 0.7MPa
  • Cv factor: body ported range 0.17 - 0.2;
    base mounted 0.25
  • Coil rated voltage: 3, 5, 6, 12, 24VDC;
    100, 110, 200, 220VAC
  • Ambient & fluid temperature: max. 50°C
Go To Bar Stock Manifold,Individual Wiring
SS5YJ5, 5000 Series, Bar Stock Manifold, Individual Wiring
  • Bar stock type manifold for SYJ5000 valves
  • Supply and exhaust ports common (20, 31, 32, 41 types)
  • Valves individually wired
  • Maximum 20 stations available as standard
  • 10 port sizes available
Go To Bar Stock Manifold,Flat Ribbon Cable
SS5YJ5, 5000 Series, Bar Stock Manifold, Flat Ribbon Cable
  • Stacking type manifold for SYJ5000 valves
  • Common supply, common exhaust
  • 26 pin connector for wiring to valves
  • Maximum 12 stations available as standard
  • 5 port sizes available
Go To 10-SYJ5000 Valve, 5 Port, For Manifold Types 20, 40, 41, 42, 43, Clean Series
10-SYJ5000 Valve, 5 Port, For Manifold Types 20, 40, 41, 42, 43, Clean Series
  • Fluid: air
  • Ambient and fluid temperature: -10 to 50° C
  • Enclosure: dustproof
  • Common exhaust for pilot and main valve
Go To 10-SYJ5000 Valve, 5 Port for Manifold Type 20P/41P/43P, Clean Series
10-SYJ5000 Valve, 5 Port for Manifold Type 20P/41P/43P, Clean Series
  • Fluid: air
  • Ambient and fluid temperature: -10 to 50° C
  • Enclosure: dustproof
  • Common exhaust for pilot and main valve
Go To 10-SS5YJ5-20, Manifold (5 Port/Body Ported), Clean Series
10-SS5YJ5-20, Manifold (5 Port/Body Ported), Clean Series
  • Single base / B mount
  • Supply and Exhaust ports common (20, 40, 41, 42, 43)
  • 2 to 20 Stations
Go To 10-SS5YJ5-40, Manifold (5 Port/Base Mounted), Clean Series
10-SS5YJ5-40, Manifold (5 Port/Base Mounted), Clean Series
  • Single base / B mount
  • Supply and Exhaust ports common (20, 40, 41, 42, 43)
  • 2 to 20 Stations
Go To 10-SS5YJ5-41, Manifold (5 Port/Base Mounted), Clean Series
10-SS5YJ5-41, Manifold (5 Port/Base Mounted), Clean Series
  • Single base / B mount
  • Supply and Exhaust ports common (20, 40, 41, 42, 43)
  • 2 to 20 Stations
Go To 10-SS5YJ5-42, Manifold (5 Port/Base Mount), Clean Series
10-SS5YJ5-42, Manifold (5 Port/Base Mount), Clean Series
  • Single base / B mount
  • Supply and Exhaust ports common (20, 40, 41, 42, 43)
  • 2 to 20 Stations
Go To 10-SS5YJ5-43, Manifold (5 Port/Base Mount), Clean Series
10-SS5YJ5-43, Manifold (5 Port/Base Mount), Clean Series
  • Single base / B mount
  • Supply and Exhaust ports common (20, 40, 41, 42, 43)
  • 2 to 20 Stations
Go To 10-SS5YJ5-20P, Manifold, Flat Ribbon Cable, (5 Port/Body Ported), Clean Series
10-SS5YJ5-20P, Manifold, Flat Ribbon Cable, (5 Port/Body Ported), Clean Series
  • Single base/b mount
  • Common SUP/EXH
  • Voltage: 12, 24 VDC; 100, 110 VAC
  • 3 to 12 stations
  • Clean appearance
Go To 10-SS5YJ5-41P, Manifold, Flat Ribbon Cable, (5 Port/Base Mounted), Clean Series
10-SS5YJ5-41P, Manifold, Flat Ribbon Cable, (5 Port/Base Mounted), Clean Series
  • Single base/b mount
  • Common SUP/EXH
  • Voltage: 12, 24 VDC; 100, 110 VAC
  • 3 to 12 stations
  • Clean appearance
Go To 10-SS5YJ5-43P, Manifold (5 Port/Base Mount), Clean Series
10-SS5YJ5-43P, Manifold (5 Port/Base Mount), Clean Series
  • Single base/b mount
  • Common SUP/EXH
  • Voltage: 12, 24 VDC; 100, 110 VAC
  • 3 to 12 stations
  • Clean appearance
 To Top